Three Phase Elektrim Induction Motor 1430 Rpm
Switching connection between the coils in each phase has a significant effect on the diameter of the wire used in the electrical motor rewinding, we sometimes encounter a situation where the diameter of the wire that we have not used in accordance with the specifications or the diameter of the wire that we need are not available , then by changing the existing connections in the stator coils, either from parallel connection turned into a series connection or series of connections turned into a parallel connection or a combination of both these connections, can be an alternative solution in rewinding electric motors.
Description
Based on 'Elektrim Induction Motor'
Rated Voltage 220V Δ/380 Y, Rated Output 7,5 Hp, Slots 36, Rated Freq 50 Hz, 1430 Rpm
Wire Diameter 0,85mm x 2, No of turns 57, Coil Span 7,9.
U1 : X1+X3
U2 : X2+X4
V1 : Z1+Z3
V2 : Z2+Z4
W1 : Y4+Y2
W2 : Y1+Y3
NEED 22KW 1400 RPM PARREL WINDING DIAGRAM
ReplyDeleteIf you are looking for motor winding diagrams, please check the BobiSoft 2.0. It is an easy-to-use, low-cost software package to (re)design motor windings. It can help you saving time and money!
ReplyDeleteThe software is recommended by WEG Portugal.
More information at
www.optisigma.pt
Any doubts? Send an e-mail to: fernando.optisigma@gmail.com
i have an (ABB) Electrical motor stator coil with the following specification>
ReplyDeletekw 420
voltages 440
RPM 1788
HZ 60
AMP. 683
SLOT 72
SPAN 1-16
PICTH 6
Please IM NOT TOO COMFORTABLE WITH THE SPAN 1-16 kindly confirm to me if the span of 1- 16 is correct.